7.3.4

Terminal assignment of the control modes

The following comparison provides information about which inputs/outputs of the application block LA_NCtrl are interconnected to the digital

and analog input/output terminals of the drive controller in the different control modes.

Control mode (

C00007

)

10:

Terminals 0

12:

Terminals 2

14:

Terminals 11

16:

Terminal 16

20:

Keypad

21:

PC

30:

CAN

40:

MCI

Digital input terminals
X5/RFR

Controller enable / Reset of error message

bFailReset

X5/DI1

Fixed setpoint 1/3

bJogSpeed1

Change of direction of

rotation

bSetSpeedCcw

Fixed setpoint 1/3

bJogSpeed1

-

-

Only if NetCtrl=0:

fixed setpoint 1/3

bJogSpeed1

X5/DI2

Fixed setpoint 2/3

bJogSpeed2

Activate manual DC-

injection braking (DCB)

bSetDCBrake

Fixed setpoint 2/3

bJogSpeed2

-

-

Only if NetCtrl=0:

fixed setpoint 2/3

bJogSpeed2

X5/DI3

Activate manual DC-

injection braking (DCB)

bSetDCBrake

Quick stop

bSetQuickstop

Motor potentiometer:

Increase speed

bMPotUp

CW rotation quick stop

bRLQCw

-

-

Only if NetCtrl=0:

Activate manual DC-injection braking (DCB)

bSetDCBrake

X5/DI4

Change of direction of rotation

bSetSpeedCcw

Motor potentiometer:

Decrease speed

bMPotDown

CCW rotation quick stop

bRLQCcw

-

-

Only if NetCtrl=0:

change of direction of rotation

bSetSpeedCcw

X5/DI5 ... DI7

-

-

-

-

-

-

-

-

Analog input terminals
X3/A1U, A1I

Local setpoint

nAuxSetValue_a

Speed mode: 10 V ≡ 100 % reference speed (

C00011

)

Torque mode: 10 V ≡ 100 % M

max

(

C00057

); speed setpoint = 100 % (fixed)

-

-

Only if NetRef=0: Local setpoint

nAuxSetValue_a

Speed mode: 10 V ≡ 100 % reference speed (

C00011

)

Torque mode: 10 V ≡ 100 % M

max

(

C00057

)

X3/A2U, A2I

-

-

-

-

-

-

-

-

Digital output terminals
X4/DO1

Status "Drive is ready"

bDriveReady

X4/DO2 ... DO3

-

-

-

-

-

-

-

-

X107/BD1, BD2

-

-

-

-

-

-

-

-

X101/COM, NO

Status "Error is pending"

bDriveFail

Analog output terminals
X3/O1U

Actual speed value

nMotorSpeedAct_a

10 V ≡ 100 % reference speed (

C00011

)

X3/O1I

-

-

-

-

-

-

-

-

X3/O2U
X3/O2I

Advertising