C01202 | mck: im motor/process, C01203 | mck: ig motor/position encoder, C01204 | mck: feed constant – Lenze 8400 HighLine User Manual

Page 1063: C01205 | mck: position resolution, C01202/1, C01202/2, C01203/1, C01203/2, C01204, C1202/1

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1063

15

Parameter reference

15.2

Parameter list | C01202

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01202

C01203

C01204

C01205

Parameter | Name:

C01202 | MCK: iM motor/process

Data type: UNSIGNED_16

Index: 23373

d

= 5B4D

h

Gearbox factor - motor

• Entry of the gearbox factor as numerator/denominator ratio (numerator = motor speed and denominator =

output speed of gearbox) or from the number of teeth of the gearbox arrangement.

Machine parameter

Setting range

(min. value | unit | max. value)

1

65535

Subcodes

Lenze setting

Info

C01202/1

1

MCK: iM: Numerator gearbox factor Z2

C01202/2

1

MCK: iM: Denominator gearbox factor Z1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01203 | MCK: iG motor/position encoder

Data type: UNSIGNED_16

Index: 23372

d

= 5B4C

h

Gearbox factor - position encoder

• Entry of the gearbox factor as numerator/denominator ratio, with numerator = motor speed and denominator

= position encoder speed.

Machine parameter

Setting range

(min. value | unit | max. value)

1

65535

Subcodes

Lenze setting

Info

C01203/1

1

MCK: iG: Numerator (motor speed)

C01203/2

1

MCK: iG: Denominator (encoder speed)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01204 | MCK: Feed constant

Data type: INTEGER_32

Index: 23371

d

= 5B4B

h

The feed constant corresponds to the movement of the machine during one revolution of the gearbox output shaft.

• The value is entered in application units referred to one revolution.

Machine parameter

Setting range

(min. value | unit | max. value)

Lenze setting

0.0001

units/rev.

214748.3647 360.0000 units/rev.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01205 | MCK: Position resolution

Data type: INTEGER_32

Index: 23370

d

= 5B4A

h

Display of the number of increments corresponding to one unit.

• 1 motor revolution ≡ 65536 increments

Machine parameter

Display range

(min. value | unit | max. value)

0.0000

Incr./unit

214748.3647

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000