17

Function library

17.1

Function blocks

1274

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.28.2 Function 2: dnIn1 > dnIn2

This function serves, for instance, to implement the comparison "actual speed is higher than a limit

value" (n

act

> n

x

) for one direction of rotation.

[17-14] Function 2: Switching performance

Functional sequence

1. If the value at dnIn1_p exceeds the value at dnIn2_p, bOut changes from FALSE to TRUE.
2. Only if the signal at dnIn1_p falls below the value of dnIn2_p - hysteresis again, bOut changes

back from TRUE to FALSE.

[17-15] Function 2: Example

C001671

: Hysteresis

TRUE

FALSE

bOut

dnIn2_p

dnIn1_p

Œ

C001671

: Hysteresis

dnIn1_p

dnIn2_p

TRUE

FALSE

bOut

t

t

Œ