C01220 | mck: ref. setting, C01220/1, 15 parameter reference – Lenze 8400 HighLine User Manual

Page 1068

Advertising
background image

15

Parameter reference

15.2

Parameter list | C01220

1068

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01220

Parameter | Name:

C01220 | MCK: Ref. setting

Data type: UNSIGNED_16

Index: 23355

d

= 5B3B

h

From version 14.00.00

Settings for "homing" mode

Homing

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0

Reserved

Bit 1

Reserved

Bit 2

Reserved

Bit 3

Reserved

Bit 4 Start deletes bHomePosAvailable

1 ≡ When homing is started (mode 4 ... 15), the reference

information is deleted.

Bit 5 Maximum jerk

1 ≡ The maximum jerk is calculated based on the

acceleration and S-ramp time of the current profile and

the sequence profile. This is then used in an accelerated

drive for reducing the acceleration to 0 or for

acceleration of the sequence profile.

Setting or activation of maximum jerk for traversing

profiles

Bit 6

Reserved

Bit 7

Reserved

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C01220/1

0x0000

MCK: Ref. setting

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising