I/O terminals

6.3

Analog terminals

352

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3.4

Internal interfaces | System block "LS_AnalogOutput"

The LS_AnalogInput system block maps the analog outputs in the FB editor.

Input

DIS code | data type

Information/possible settings

nOut1V_a

C00439/1

| INT

Analog output 1 (voltage)

• Scaling: 2

14

≡ 16384 ≡ 10 V

nOut1I_a

C00439/3

| INT

Analog output 1 (current)

• Scaling: 2

14

≡ 16384 ≡ 20 mA

nOut2V_a

C00439/2

| INT

Analog output 2 (voltage)

• Scaling: 2

14

≡ 16384 ≡ 10 V

nOut2I_a

C00439/4

| INT

Analog output 2 (current)

• Scaling: 2

14

≡ 16384 ≡ 20 mA