15

Parameter reference

15.2

Parameter list | C02610

1132

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02610

C02611

Parameter | Name:

C02610 | MCK: Accel./decel. times

Data type: UNSIGNED_32

Index: 21965

d

= 55CD

h

Ramp times for speed setpoint synchronisation
Setting range

(min. value | unit | max. value)

0.000

s

999.999

Subcodes

Lenze setting

Info

C02610/1

2.000 s

Holding brake: ramp time synchr.

• Ramp time for the synchronisation process to

setpoint speed after the brake opening time has

elapsed

Revised behaviour from version 11.00.00:

• The setting made here is only effective if bit 6

"SyncRampe L_NSet_1" in

C02582

is set to "0".

• In the Lenze setting of

C02582

(Bit 6 = "1"), the ramp

time of the effective acceleration of the ramp

function generator (

L_NSet_1

) is used.

Holding brake control

C02610/2

2.000 s

MCK: Ramp time synchr. setpoint

• Time for synchronisation ramps between setpoint

jumps occurring through the exceedance of

minimum and maximum speed setpoint limit ranges.

C02610/3

2.000 s

MCK: SM stopping ramp

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C02611 | MCK: Limitations

Data type: INTEGER_16

Index: 21964

d

= 55CC

h

Speed setpoint limits for the determination of limited validity ranges

Note:

Traversing with setpoints through resulting blocking zones is executed with the ramp set in

C02610/2

.

Speed Min/Max

Setting range

(min. value | unit | max. value)

0.00

%

199.99

Subcodes

Lenze setting

Info

C02611/1

199.99 %

MCK: Pos. max. speed

• Upper limit of the speed setpoint limitation in

positive direction of rotation.

C02611/2

0.00 %

MCK: Pos. min. speed

• Lower limit of the speed setpoint limitation in

positive direction of rotation.

C02611/3

0.00 %

MCK: Neg. min. speed

• Lower limit of the speed setpoint limitation in

negative direction of rotation.

C02611/4

199.99 %

MCK: Neg. max. speed

• Upper limit of the speed setpoint limitation in

negative direction of rotation.

C02611/5

0.50 %

MCK: Max. speed

From version 12.00.00

• Maximum value for transferring the current speed to

the speed setpoint when the internal operating mode

"

StandBy

" is exited.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100