1083

15

Parameter reference

15.2

Parameter list | C01252

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01252

C01294

C01295

Parameter | Name:

C01252 | MCK: S-ramp times stop

Data type: UNSIGNED_16

Index: 23323

d

= 5B1B

h

S-ramp times for stop

• Setting "0 s" ≡ no rounding

Stop

Setting range

(min. value | unit | max. value)

0.000

s

10.000

Subcodes

Lenze setting

Info

C01252/1

0.000 s

MCK: Stop: S-ramp time

• S-ramp time for setpoint speed ramp-down to

standstill.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01294 | Mode: Position calculation

Data type: UNSIGNED_8

Index: 23281

d

= 5AF1

h

From version 12.00.00

Selection of the conversion mode
Selection list

0 dnOut_p=ConvWordsToDInt(HW_L

W)

1 16 bits: LW=+/-32767
2 16 bits: HW=+/-; LW=0..65535
3 32Bit: HW_LW=+/-214748.3647

Subcodes

Lenze setting

Info

C01294/1

0:

dnOut_p=ConvWordsToDInt(HW_L

W)

L_ConvUnitsToIncr_1

: PosCalcMode

C01294/2

0:

dnOut_p=ConvWordsToDInt(HW_L

W)

L_ConvUnitsToIncr_2

: PosCalcMode

C01294/3

0:

dnOut_p=ConvWordsToDInt(HW_L

W)

L_ConvUnitsToIncr_3

: PosCalcMode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01295 | L_MCKStateInterface_1: Pos. selection

Data type: UNSIGNED_8

Index: 23280

d

= 5AF0

h

From version 04.00.00

Selection of the position to be provided at the dnPosOut_p output of the FB

L_MckStateInterface

Selection list

(Lenze setting printed in bold)

0 dnPosIn_p
1 Current feed
2 dnSetPos_p
3 dnActPos_p
4 dnDeltaPos_p
5 dnTargetPos_p

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1