3commissioning – Lenze 8400 HighLine User Manual

Page 80

Advertising
background image

3

Commissioning

3.9

Commissioning of the "Switch-off positioning" technology application

80

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.9

Commissioning of the "Switch-off positioning" technology application

[3-3]

Block diagram for wiring of the commissioning example for the "Switch-off positioning" application

Note!

Take all the necessary safety precautions before you carry out the following

commissioning steps and switch the device on!

Safety instructions with regard to commissioning

( 51)

System constellation

X4/RFR

Controller enable

X5/DI1

Initiator connection for stop function 1

X5/DI2

Initiator connection for stop function 2

X5/DI3

Quick stop for CW rotation / selection of switch-off position 1

X5/DI4

Quick stop for CCW rotation / selection of switch-off position 2

X6

Diagnostic interface for connecting the USB diagnostic adapter

8400 HighLine

X61

X6

DIAG

AR A1U GA

X3

24I RFR DI1 DI2

X5

DI3 DI4 DI5 DI6 DI7

U V W

X6

t [s]

0
1

QSP

Cw

Ccw

-

DI1

DI2

DI1

DI2

v [m/s]

C00039/3

C00012

C00012

C00013

C00039/3

C00013

Cw
Ccw

Cw

Ccw

M

3~

i

0
1

0
0

1

1