5 activate/deactivate quick stop, Activate/deactivate quick stop, Activate/deactivate quick stop ( 106) – Lenze 8400 HighLine User Manual

Page 106: 4device control (dctrl)

Advertising
background image

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

106

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.5

Activate/deactivate quick stop

The

C00002/17

= "1: On / start" device command activates the quick stop function, i.e. the motor

control is separated from the setpoint selection, and within the deceleration time parameterised

in

C00105

the motor is brought to a standstill (n

act

= 0).

• The motor is kept at a standstill during closed-loop operation.
• A pulse inhibit is set if the auto-DCB function has been activated via

C00019

.

From version 10.00.00

, further options for the quick stop function can be activated in

C00104/1

.

Optional settings

( 107)

C00159

provides a bit coded representation of all active sources/triggers of a quick stop:

Deactivate quick stop again
The

C00002/17

= "0: Off / ready" device command deactivates the quick stop again, provided that

no other source of a quick stop is active.

Parameter

Info

Lenze setting

Value Unit

C00105

Decel. time - quick stop

2.000 s

Bit Cause/source for quick stop

Bit 0

Reserved

Bit 1 CAN control word (bit 2)
Bit 2 MCI control word (bit 2)
Bit 3

Reserved

Bit 4 Application (

LS_MotorInterface

system block: bQspOn input)

Bit 5 Device command (

C00002/17

)

Bit 6 Device error with "TroubleQSP" error response
Bit 7 Internal signal
Bit 8

Reserved

Bit 9

Reserved

Bit 10 Operating system
Bit 11

Reserved

Bit 12 MCK (System block

LS_MotionControlKernel

: Input bQspOn)

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved