C01068 | l_switchpoint_1: invert, C01069 | l_dfset_1: ramp settings, 15 parameter reference – Lenze 8400 HighLine User Manual

Page 1046

Advertising
background image

15

Parameter reference

15.2

Parameter list | C01068

1046

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01068

C01069

Parameter | Name:

C01068 | L_SwitchPoint_1: Invert

Data type: UNSIGNED_16

Index: 23507

d

= 5BD3

h

From version 12.00.00

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Invert Output1

Bit set = inversion active

Bit 1 Invert Output2
Bit 2 Invert Output3
Bit 3 Invert Output4
Bit 4

Reserved

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C01068/1

0x0000

L_SwitchPoint_1

: Inversion of outputs

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01069 | L_DFSET_1: Ramp settings

Data type: UNSIGNED_16

Index: 23506

d

= 5BD2

h

From version 11.00.00

Setting range

(min. value | unit | max. value)

0

Incr./ms

32767

Subcodes

Lenze setting

Info

C01069/1

10 incr./ms

L_DFSET_1

: Ramp SpeedTrim (1/100)

From version 12.00.00 onwards

, this setting has a

resolution increased by the factor 100: A value of

32767 is internally evaluated with 327.67. Hence, the

unit is [incr./100 ms].

C01069/2

100 incr./ms

L_DFSET_1

: Ramp angle compensation

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising