C00950 | l_interpolator_1: activation fb functions, C00953 | l_interpolator_1: speed-up, 15 parameter reference – Lenze 8400 HighLine User Manual

Page 1022

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00950

1022

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00950

C00951

C00952

C00953

Parameter | Name:

C00950 | L_Interpolator_1: Activation FB functions

Data type: UNSIGNED_8

Index: 23625

d

= 5C49

h

From version 04.00.00

The

L_Interpolator_1

FB: Activation of signal interpolation and signal monitoring

Selection list

0 Off
1 On

Subcodes

Lenze setting

Info

C00950/1

0: Off

L_Interpolator_1

: Signal interpolation

C00950/2

0: Off

L_Interpolator_1

: Signal monitoring

C00950/3

0: Off

L_Interpolator_1

: Master value monitoring

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00951 | L_Interpolator_1: No. of interpolation steps

Data type: UNSIGNED_16

Index: 23624

d

= 5C48

h

From version 04.00.00

The

L_Interpolator_1

FB: No. of interpolation steps

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00952 | L_Interpolator_1: Limit value - error cycles

Data type: UNSIGNED_16

Index: 23623

d

= 5C47

h

From version 04.00.00

The

L_Interpolator_1

FB: Limit value for missing data telegrams

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 5

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00953 | L_Interpolator_1: Speed-up

Data type: UNSIGNED_8

Index: 23622

d

= 5C46

h

From version 04.00.00

FB

L_Interpolator_1

: Limitation of the number of correction increments per cycle (speed-up)

Setting range

(min. value | unit | max. value)

Lenze setting

0

100 0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1