6i/o terminals – Lenze 8400 HighLine User Manual

Page 327

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

327

6

I/O terminals

6.1

Digital input terminals

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Internal interfaces to the application

• Relevant inputs at the

LS_DigitalInput

system block:

• Relevant outputs at the

LS_DigitalInput

system block:

Related topics:

Output of the encoder position of the DI1/DI2 frequency input

( 335)

Using DI1(6) and DI2(7) as digital inputs

( 322)

Using DI1(6) as counting input

( 328)

Internal interfaces | System block "LS_DigitalInput"

( 332)

Input

Data type

Information/possible settings

Frequency input DI1/DI2
bPosIn12_Load

BOOL

(from version 06.00.00)

Load angle integrator with starting value and reset status signal

TRUE Angle integrator is loaded with the value at dnPosIn12_Set_p and

bPosIn12_State is reset to FALSE.

dnPosIn12_Set_p

DINT

(from version 06.00.00)

Starting value for angle integrator

Output

Data type

Value/meaning

Frequency input DI1/DI2
nFreqIn12_a

C00446/1

| INT

Output frequency as scaled analog signal in [%]

nFreqIn12_v

C00445/1

| INT

Output frequency as speed signal in [inc/ms]

dnPosIn12_p

DINT

(from version 06.00.00)

Angle output signal

• 65536 [incr.] ≡ 1 encoder revolution

• Overflow is possible (display via bPosIn12_State)

bPosIn12_State

BOOL

(from version 06.00.00)

Status signal "Overflow occurred/distance processed"

• Status signal can be reset via bPosIn12_Load.

TRUE Overflow has occurred or distance is processed.

Frequency input DI6/DI7
nFreqIn67_a

C00446/2

| INT

Output frequency as scaled analog signal in [%]

nFreqIn67_v

C00445/2

| INT

Output frequency as speed signal in [inc/ms]

Advertising