Commissioning

3.8

Commissioning of the "Table positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.8

Commissioning of the "Table positioning" technology application

[3-2]

Block diagram for wiring the commissioning example for the "Table positioning" application

Note!

Take all the necessary safety precautions before you carry out the following

commissioning steps and switch the device on!

Safety instructions with regard to commissioning

( 51)

System constellation

X5/RFR

Controller enable

X5/DI1

Position encoder connection, track A

X5/DI2

Position encoder connection, track B

X5/DI3

Hardware limit switch connection in positive direction

X5/DI4

Hardware limit switch connection in negative direction

X5/DI5/DI6 Profile selection and change of operating mode at the same time:

0 | 0 = Profile selection 0 and request for "Speed follower" operating mode

0 | 1 = Profile selection 1 and request for "Homing" operating mode

1 | 0 = Profile selection 2 and request for "Manual jog" operating mode

1 | 1 = Profile selection 3 and request for "Positioning" operating mode

X5/DI7

Start of profile generation

X6

Diagnostic interface for connecting the USB diagnostic adapter

8400 HighLine

X61

X6

DIAG

AR A1U GA

X3

24I RFR DI1 DI2

X5

DI3 DI4 DI5 DI6 DI7

U V W

X6

M

3~

0-Position

20

30

10

-10

-20

-30

40

i

A

B

DI7: PosExecute

DI5/DI6: PosProfile 0 ... 3