C01246

C01247

Parameter | Name:

C01246 | MCK: Select signal source

Data type: UNSIGNED_8

Index: 23329

d

= 5B21

h

From version 06.00.00

Selection of the touch probe signal source for reference search with touch probe detection

• If the reference signal is to follow a real touch probe, the

Touch-Probe-Interface

must be configured accordingly.

Homing

Selection list

0 No TP
3 TP-DigIn3
4 TP-DigIn4
5 TP-DigIn5
6 TP-DigIn6
7 TP-DigIn7

Subcodes

Lenze setting

Info

C01246/1

0: No TP

MCK: Ref. TP signal source

Note:

In case of setting "0: No TP", the digital input DI3 is used

as signal source for reference search. An inversion of DI3

via

C00114

is considered.

C01246/2

0: No TP

MCK: Set.Ref. signal source

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01247 | MCK: Diagnostic word

Data type: UNSIGNED_32

Index: 23328

d

= 5B20

h

From version 15.00.00

Display area

(min. hex value | max. hex value)

0x00000000

0xFFFFFFFF

Value is bit-coded:

Info

Bit 0 Traversing range: Limited

1 ≡ The traversing range is limited:

• The software limit positions are set.

• The reference is known.

• There is no modulo measuring system available

(

C01201/1

= 0).

Note:

This status does not consider whether the software limit

positions are activated or deactivated by the settings in

the prevailing operating mode.

Bit 1 Traversing range: Modulo

1 ≡ A modulo measuring system is available as a cycle

length has been set in

C01201/1

.

Bit 2

Reserved

Bit 3

Reserved

Bit 4

Reserved

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8 SpeedNormConstant: Low-Limit

1 ≡ Due to the set machine parameters, an internal

calculation constant is limited to a possible minimum.

Remedy: Increase reference speed in

C00011

.