Xx.0184.00001, Xx.0145.00035, Xx.0145.00050 – Lenze 8400 HighLine User Manual

Page 662: Xx.0145.00051, Xx.0145.00052, 9diagnostics & error management

Advertising
background image

9

Diagnostics & error management

9.9

Error messages of the operating system

662

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

dF10: AutoTrip reset [xx.0145.00035]

dF50: Retain error [xx.0145.00050]

dF51: CuCcr error [xx.0145.00051]

dF52: BuCcr error [xx.0145.00052]

Ck01: Pos. HW limit switch [xx.0184.00001]

Response (Lenze setting printed in bold)

Setting:

C00189

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Too frequent auto-trip reset.

• Check the error cause that activates the auto-trip

reset.

• Eliminate error cause and reset (acknowledge) error

manually afterwards.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

An error has occurred when accessing retain data.

• Either caused by an internal hardware error or by lack

of mains switching after a firmware download.

Mains switching

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Mains switching

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Mains switching

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

Setting:

C00595/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The hardware limit switch in positive traversing

direction has tripped.

• The bLimitSwitchPos input for travel range

monitoring via positive hardware limit switch has

been set to FALSE (fail-safe).

Reset error message and retract limit switch.

Advertising