2 auto-start option "inhibit at lenze setting, Auto-start option "inhibit at lenze setting, 4device control (dctrl) – Lenze 8400 HighLine User Manual

Page 124: Nr o p, No p

Advertising
background image

4

Device control (DCTRL)

4.3

Automatic restart after mains connection/fault...

124

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.3.2

Auto-start option "Inhibit at Lenze setting"

This function extension is available from version 06.00.00!

The "Inhibit at Lenze setting" auto-start option configurable via bit 4 of

C00142

prevents the

change to the "

SwitchedOn

" status after the Lenze setting has been loaded and the controller is

enabled.
For a change to the "

SwitchedOn

" status, the controller enable must first be deactivated after the

Lenze setting has been loaded. Only if the controller is enabled again afterwards, the status changes

to "

OperationEnabled

":

[4-1]

Example 1: Behaviour with activated auto-start option "Inhibit at Lenze setting" (

C00142

: Bit 4 = "1")

[4-2]

Example 2: Behaviour with deactivated auto-start option "Inhibit at Lenze setting" (

C00142

: Bit 4 = "0")

Loading of the Lenze setting not possible since controller inhibit not set.

Controller inhibit via signal change by the user

Loading of the Lenze setting via device command

C00002/1

= "1"

Controller enable via signal change by the user

Controller inhibit and subsequent controller enable via signal change by the user

t

load

= time required for loading the Lenze setting

,QLW

5HDG\7R6ZLWFK2Q

6ZLWFKHG2Q

2SHUDWLRQ(QDEOHG





&

/$B1&WUOE&,QK

W

W





5)5

W





&

W

n

r

o

p

W

ORDG

q

Loading of the Lenze setting not possible since controller inhibit not set.

Controller inhibit via signal change by the user

Loading of the Lenze setting via device command

C00002/1

= "1"

Controller enable via signal change by the user

t

load

= time required for loading the Lenze setting

,QLW

5HDG\7R6ZLWFK2Q

6ZLWFKHG2Q

2SHUDWLRQ(QDEOHG





&

/$B1&WUOE&,QK

W

W





5)5

W





&

W

W

n

o

p

ORDG

q

Advertising