C00478 | ls_parfree_v_2, C00479 | ls_parfree32, C00480 | ls_disfree_b – Lenze 8400 HighLine User Manual

Page 902: 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00478

902

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00478

C00479

C00480

Parameter | Name:

C00478 | LS_ParFree_v_2

Data type: INTEGER_16

Index: 24097

d

= 5E21

h

From version 11.00.00

SB

LS_ParFree_v_2

: Setting of the speed signals to be output

Setting range

(min. value | unit | max. value)

-32767

Incr./ms

32767

Subcodes

Lenze setting

Info

C00478/1

0 incr./ms

Values for output nC478_1_v ... nC478_8_v

C00478/...
C00478/8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00479 | LS_ParFree32

Data type: INTEGER_32

Index: 24096

d

= 5E20

h

From version 11.00.00

SB

LS_ParFree32

: Setting of the 32-bit values to be output

Setting range

(min. value | unit | max. value)

-2147483647

2147483647

Subcodes

Lenze setting

Info

C00479/1

0

Values for output dnC479_1 ... dnC479_8

C00479/...
C00479/8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00480 | LS_DisFree_b

Data type: UNSIGNED_16

Index: 24095

d

= 5E1F

h

The

LS_DisFree_b

SB: Display of the input values

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 bDis1

Signal level input bDis1 ... bDis16

... ...

Bit 15 bDis16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising