Working with the FB Editor

16.4

Reconfiguring the predefined interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

• The buttons serve to execute the following functions:

16.4.7

Resetting changed interconnection

If you only made changes on the I/O level, you can reset them by selecting a predefined control

scheme in

C00007

. If you have also made changes on the application level, you must first reset the

changed application to a predefined application in

C00005

.

How to reset the application interconnection to a predefined application:

1. Go to the Application parameters tab.
2. Select the required application in the Application list field.

How to reset the I/O interconnection to a predefined control scheme:

1. Go to the Application parameters tab.
2. Select the required control scheme in the Control source list field.

Button

Function

Insert

Add elements selected in the list to the target interconnection

• Only possible if at least one element in the list has been selected for insertion.

• Insertion is also possible via the <Enter> button if at least one element is selected from

the list for insertion.

• The original layout and the relative position of the inserted blocks to each other are

maintained.

• When copying across the devices, you also insert the corresponding separate technical

objects (e.g. port definition).

• The added elements are simultaneously deleted from the list. The connections are added

depending on the selected option.

Close

Close dialog box.

• You can also use <Esc> or <Enter> to close the dialog box if "Insert" is not active.

• The elements inserted into the target interconnection so far are maintained.

• The connections for the blocks inserted so far are inserted depending on the selected

option.