8basic drive functions (mck) – Lenze 8400 HighLine User Manual

Page 503

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

503

8

Basic drive functions (MCK)

8.2

Internal interfaces | System block "LS_MotionControlKernel"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

MCK status word 2 (wMotionState2)

Bit

Designation

Description

16 DwellTime

"1" ≡ Dwell time after reaching the setpoint position is active.

Target position monitoring (status "drive in target")

17 InTarget

"1" ≡ Dwell time has expired and current actual position is in the set target window.

Target position monitoring (status "drive in target")

18 PosDone

"1" ≡ Positioning profile has been completed in the "Positioning" or "Homing" mode.

Setpoint position of a profile data set is in target.

19 Reserved

-

20

...

23

ActPosMode_Bit00

...

ActPosMode_Bit03

Active positioning mode

Bit 3

Bit 2

Bit 1

Bit 0

Absolute (shortest path)

0

0

0

1

Continuous

0

0

1

0

Relative

0

0

1

1

Absolute (Cw)

*

0

1

0

0

Absolute (Ccw)

*

0

1

0

1

Absolute (shortest path) to TP

*

1

0

0

0

Continuous to TP

*

1

0

0

1

Relative to TP

*

1

0

1

0

Absolute (Cw) to TP

*

1

0

1

1

Absolute (Ccw) to TP

*

1

1

0

0

* From version 06.00.00

Note: The display of the active positioning mode depends on further factors. See

subchapter "

Override of the parameterised positioning mode

".

24

...

31

ActProfileNo_Bit00

...

ActProfileNo_Bit07

Active profile

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Profile 0

0

0

0

0

0

0

0

0

Profile 1

0

0

0

0

0

0

0

1

Profile 2

0

0

0

0

0

0

1

0

...

...

Profile 15

0

0

0

0

1

1

1

1

Note!

The effective positioning mode is generated via the MCK control word (bit 20 ... 23)

and/or the parameters

C01300/1...15

for defining the positioning mode in the profile

data. Here, the setting in the MCK control word superimposes the mode selection via the

corresponding parameter. This means that the mode selection and the touch probe

enable are possible via process data.
For generating the effective positioning mode, the following applies:

• Valid PosMode in the MCK control word:

Use positioning mode of the MCK control word

• PosMode in the MCK control word = 0:

Use positioning mode set in

C01300/x

• Invalid PosMode in the MCK control word:

Error message "Ck09: Positioning mode invalid"