C01221 | mck: ref. mode, C01222 | mck: ref. m limit mode 14/15, C01221 – Lenze 8400 HighLine User Manual

Page 1069: C01222, 15 parameter reference

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1069

15

Parameter reference

15.2

Parameter list | C01221

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01221

C01222

Parameter | Name:

C01221 | MCK: Ref. mode

Data type: UNSIGNED_8

Index: 23354

d

= 5B3A

h

Selection of the homing mode.

Homing

Selection list

(Lenze setting printed in bold)

Info

4 >_Rp_<_TP

Positive direction - reversing on pre-stop mark (pos.

edge) - to touch probe

From version 14.00.00

5 <_Rp_>_TP

Negative direction - reversing on pre-stop mark (pos.

edge) - to touch probe

From version 14.00.00

6 >_Rn_>_TP

Positive direction - via pre-stop mark (neg. edge) -

continuing in positive direction - to touch probe

7 <_Rn_<_TP

Negative direction - via pre-stop mark (neg. edge) -

continuing in negativee direction - to touch probe

8 >_TP

Positive direction - to touch probe

9 <_TP

Negative direction - to touch probe

10 >_Lp_<_TP

Positive direction - reversing on pos. limit switch - to

touch probe

11 <_Ln_>_TP

Negative direction - reversing on neg. limit switch - to

touch probe

12 >_Lp

Positive direction - to pos. limit switch

13 <_Ln

Negative direction - to neg. limit switch

14 >_Mlim

Positive direction towards torque limit (

C01222

)

15 <_Mlim

Negative direction towards torque limit (

C01222

)

100 SetRef

Direct acceptance and setting of the home position

• The measuring system is set based on the home

position parameterised in

C01227/2

when the drive is

at standstill.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01222 | MCK: Ref. M limit mode 14/15

Data type: INTEGER_16

Index: 23353

d

= 5B39

h

Torque limit for homing modes 14 and 15 (homing towards positive stop)

• 100 % ≡ maximum torque (

C00057

)

Homing

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

199.99 10.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising