Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

401

7

Technology applications

7.3

TA "actuating drive speed (AC Drive Profile)"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Selection of the torque setpoint in torque mode
In torque mode", the nTorqueGenLim_a application input has the function of the torque setpoint

selection.
The torque setpoint is usually defined as process date via the fieldbus. If set accordingly, the torque

setpoint can also be determined locally (e.g. via the analog input 1).
For the local selection of the torque setpoint, the same application input (nAuxSetValue_a) is used

as for the local selection of the speed setpoint. In "torque mode" however, the nAuxSetValue_a

input is internally connected to the nTorqueGenLim_a input. In this case, the speed setpoint is

internally permanently set to "100 %".
The relationships are shown in the following table:

Fieldbus used

Control mode

(

C00007

)

Torque

reference

AC Drive Profile control word

(wMCIDriveControl)

effective input

(at LA_NCtrl)

40: MCI

via fieldbus

(data word 3)

Bit 6 ("NetRef") = 1

nTorqueGenLim_a

local*

Bit 6 ("NetRef") = 0

nAuxSetValue_a

30: CAN

via fieldbus

(data word 3)

Bit 6 ("NetRef") = 1

nTorqueGenLim_a

local*

Bit 6 ("NetRef") = 0

nAuxSetValue_a

-

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

local*

9 ≡ 0x0009

• Bit 0, SwitchOn = TRUE

• Bit 3, EnableOperation = TRUE

• All others: FALSE

nAuxSetValue_a

20: Keypad

C00728/3

21: PC

C00472/1

* The local setpoint is selected in the Lenze setting via the analog input 1