2

Introduction: Parameterising the controller

2.3

General notes on parameters

34

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.3.1

Changing the parameterisation with the keypad

Keypad display and control elements

The keypad is simply plugged on the diagnostic

interface X6 ("DIAG") at the front of the standard

device.
Plugging and unplugging the keypad is possible

during operation.

LCD display
Headline
In the menu level: Menu name

In the parameter level: Parameter name
Three-part display
In the menu level: List of available menus

In the parameter level: Code/subcode and setting or actual value
Device status

Controller is switched on

Pulse inhibit active

Controller is enabled

System fault active

Controller is inhibited

"Fault" device status is active

Quick stop active

"Trouble" device status is active

Current limit exceeded

"TroubleQSP" device status is active

Speed controller 1 in the limitation

A warning is indicated

WXST

VYR