3commissioning – Lenze 8400 HighLine User Manual
Page 96
3
Commissioning
3.10
PC manual control
96
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to carry out positioning:
1. Select the profile to be travelled (1 ... 15) in the Profile number list field.
2. If the controller is still inhibited, enable the controller via the Enable controller button.
• Please observe that the controller will not be enabled if other sources of controller
inhibit (e.g. terminal RFR) are active.
If the controller is in the "OperationEnabled" device status:
3. Click the Run POS button to start the positioning process.
• Click the Stop POS button to stop an active positioning process anytime.