Parameter reference

15.2

Parameter list | C01234

1074

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01234

C01235

C01236

Parameter | Name:

C01234 | MCK: Manual jog breakpoints

Data type: INTEGER_32

Index: 23341

d

= 5B2D

h

Breakpoint positions for manual jog

• The drive stops at the parameterised positions if these are located in the manual jog direction and the

approaching of the breakpoints is switched on in

C01230

via bit 0.

Manual jog

Setting range

(min. value | unit | max. value)

-214748.3647

unit

214748.3647

Subcodes

Lenze setting

Info

C01234/1

0.0000 unit

Manual jog: Breakpoint 1

C01234/2

0.0000 unit

Manual jog: Breakpoint 2

C01234/3

0.0000 unit

Manual jog: Breakpoint 3

C01234/4

0.0000 unit

Manual jog: Breakpoint 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01235 | MCK: Manual jog waiting times

Data type: UNSIGNED_16

Index: 23340

d

= 5B2C

h

Waiting times for manual jog

Manual jog

Setting range

(min. value | unit | max. value)

0.000

s

65.000

Subcodes

Lenze setting

Info

C01235/1

5.000 s

Manual jog: Waiting time 2nd speed

• Time after which the first manual speed (

C01231/1

) is

accelerated to the second manual speed (

C01231/2

).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01236 | MCK: Speed follower

Data type: INTEGER_32

Index: 23339

d

= 5B2B

h

Speeds for position follower

Position follower

Setting range

(min. value | unit | max. value)

-214748.3647

units/s

214748.3647

Subcodes

Lenze setting

Info

C01236/1

360.0000 units/s

PosFollower: Sync. speed

• Synchronisation speed for approaching the setpoint

position of the master.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000