3 set/reset home position, Set/reset home position, 3commissioning – Lenze 8400 HighLine User Manual

Page 93

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

93

3

Commissioning

3.10

PC manual control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.10.3

Set/reset home position

The measuring system in the machine is selected by means of homing and the 0 position is set

within the possible physical travel range.

The changeover to the "Homing" operating mode is effected by selecting the option of the same

name on the Positioning tab:

How to set the reference manually with standing drive:
Click the Set reference button.
The current actual position in the machine measuring system now corresponds to the

home position set in

C01227/2

(Lenze setting: 0.0000 units).

Detailed information on the "Homing" operating mode is provided in chapter "Basic

drive functions" in subchapter "

Homing

".

( 546)

Stop!

If you set the reference with PC manual control, the drive is referenced with it.
If another home position is used for normal operation:
Click the Cancel reference button and reset the status signals HomPosAvailable and

HomePosDone in the MCK status word in order that no mechanical problems can occur

during normal operation.

• Setpoints and actual positions remain untouched until a renewed reference setting or

homing.