Synchronisation mode - mark

correction

0 Synchronisation inactive

Lenze setting

1 Permanent synchronisation without

enable via the bZeroPulse input

• Correction is executed over the

shortest possible path.

The synchronisation only takes place

after 2 setpoint pulses have been

received at the bSetTPReceived input.

(required pulse order: set-actual-set)

2 Permanent synchronisation only

with enable via the bZeroPulse input

• When bZeroPulse is set to TRUE, a

permanent zero pulse/touch

probe synchronisation is

executed.

• Correction is executed over the

shortest possible path.

10 One-time synchronisation

• An angular difference is

compensated over the shortest

possible path.

11 One-time synchronisation

• An angle difference is

compensated in CW direction.

12 One-time synchronisation

• An angular difference is

compensated in CCW direction.

13 One-time synchronisation

• An angular difference is

compensated over the shortest

possible path.

Synchronisation takes place after the

first setpoint pulse has been received

at the bSetTPReceived input and/or

actual value pulse at the

bActTPReceived input.

(Required clock sequence: Set/actual

or actual/set)

Parameter

Possible settings

Info