15 parameter reference, 6 table of attributes – Lenze 8400 HighLine User Manual

Page 1173

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1173

15

Parameter reference

15.6

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00918

SC: Start motor magnetising current

Linear value

23657

5C69

E

1

UNSIGNED_8

1

C00919

Load moment of inertia

Linear value

23656

5C68

A

1

UNSIGNED_32

100

C00937

Field-oriented motor currents

Linear value

23638

5C56

A

2

INTEGER_16

100

C00938

PSM: Maximum motor current field

weakening

Linear value

23637

5C55

E

1

UNSIGNED_16

100

C00939

Ultimate motor current

Linear value

23636

5C54

E

1

UNSIGNED_16

10

C00940

L_ConvW numerator

Linear value

23635

5C53

A

4

INTEGER_16

1

C00941

L_ConvW denominator

Linear value

23634

5C52

A

4

INTEGER_16

1

C00942

L_ConvW conversion method

Selection list

23633

5C51

A

4

UNSIGNED_8

1

C00950

L_Interpolator_1: Activation FB functions

Selection list

23625

5C49

A

3

UNSIGNED_8

1

C00951

L_Interpolator_1: No. of interpolation

steps

Linear value

23624

5C48

E

1

UNSIGNED_16

1

C00952

L_Interpolator_1: Limit value - error cycles Linear value

23623

5C47

E

1

UNSIGNED_16

1

C00953

L_Interpolator_1: Speed-up

Linear value

23622

5C46

E

1

UNSIGNED_8

1

C00959

L_Curve: Current output value

Linear value

23616

5C40

A

3

INTEGER_16

100

C00960

L_Curve_1: Selected curve type

Selection list

23615

5C3F

A

1

UNSIGNED_8

1

C00961

L_Curve_1: Input limitation

Linear value

23614

5C3E

A

2

INTEGER_16

100

C00963

L_Curve_1: Table X-values

Linear value

23612

5C3C

A

32

INTEGER_16

1

C00964

L_Curve_1: Table Y-values

Linear value

23611

5C3B

A

32

INTEGER_16

1

C00965

Max. motor speed

Linear value

23610

5C3A

E

1

UNSIGNED_16

1

C00966

VFC: Time const. slip comp.

Linear value

23609

5C39

E

1

UNSIGNED_16

1

C00967

VFC: Frequency interpol. point n

Linear value

23608

5C38

A

11

INTEGER_16

10

C00968

VFC: Voltage interpol. point n

Linear value

23607

5C37

A

11

UNSIGNED_16

100

C00969

Motorparameter

Linear value

23606

5C36

A

1

UNSIGNED_8

1

C00971

VFC: V/f +encoder limitation

Linear value

23604

5C34

A

2

UNSIGNED_16

100

C00972

VFC: Vp V/f +encoder

Linear value

23603

5C33

E

1

UNSIGNED_16

1000

C00973

VFC: Ti V/f +encoder

Linear value

23602

5C32

E

1

UNSIGNED_16

10

C00975

VFC-ECO: Vp CosPhi controller

Linear value

23600

5C30

E

1

UNSIGNED_16

1000

C00976

VFC-ECO: Ti CosPhi controller

Linear value

23599

5C2F

E

1

UNSIGNED_16

10

C00977

VFC-ECO: Minimum voltage V/f

Linear value

23598

5C2E

E

1

INTEGER_16

100

C00978

VFC-ECO: Voltage reduction

Linear value

23597

5C2D

E

1

INTEGER_16

1

C00979

Cosine phi

Linear value

23596

5C2C

A

2

INTEGER_16

100

C00980

Output power

Linear value

23595

5C2B

A

2

INTEGER_32

1000

C00981

Energy display

Linear value

23594

5C2A

A

2

INTEGER_32

100

C00982

VFC-ECO: Voltage reduction ramp

Linear value

23593

5C29

E

1

UNSIGNED_8

10

C00983

Delay

Linear value

23592

5C28

A

2

UNSIGNED_16

1

C00985

SLVC: Field current controller gain

Linear value

23590

5C26

E

1

INTEGER_16

100

C00986

SLVC: Cross current controller gain

Linear value

23589

5C25

E

1

INTEGER_16

100

C00987

Inverter motor brake: nAdd

Linear value

23588

5C24

E

1

INTEGER_16

1

C00988

Inverter motor brake: PT1 filter time

Linear value

23587

5C23

E

1

INTEGER_16

10

C00989

Restart on the fly: Flying restart frequency

fd_add

Linear value

23586

5C22

A

1

INTEGER_16

100

C00990

Flying restart fct.: Activate

Selection list

23585

5C21

E

1

UNSIGNED_8

1 CINH

C00991

Flying restart fct.: Process

Selection list

23584

5C20

E

1

UNSIGNED_16

1

C00992

Flying restart fct.: Start frequency

Linear value

23583

5C1F

E

1

INTEGER_16

1

C00993

Flying restart fct: Int. time

Linear value

23582

5C1E

E

1

UNSIGNED_16

10

C00994

Flying restart fct.: Current

Linear value

23581

5C1D

E

1

INTEGER_16

100

C00995

SLPSM: Controlled current setpoint

Linear value

23580

5C1C

A

2

UNSIGNED_16

100

C00996

SLPSM: Switching speed

Linear value

23579

5C1B

A

2

INTEGER_16

100

C00997

SLPSM: Filter cutoff frequency

Linear value

23578

5C1A

E

1

INTEGER_16

100

C00998

SLPSM: Filter time rotor position

Linear value

23577

5C19

A

2

INTEGER_16

10

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH

Grayed out = display parameter (read access only)

Advertising