15

Parameter reference

15.2

Parameter list | C01226

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01226

C01227

C01228

Parameter | Name:

C01226 | MCK: Ref. S-ramp time

Data type: UNSIGNED_16

Index: 23349

d

= 5B35

h

S-ramp time for reference search/homing

• Setting "0 s" ≡ no rounding

Homing

Setting range

(min. value | unit | max. value)

0.000

s

10.000

Subcodes

Lenze setting

Info

C01226/1

0.000 s

MCK: Ref. S-ramp time

• S-ramp time for the starting and search speed ramps.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01227 | MCK: Ref. positions

Data type: INTEGER_32

Index: 23348

d

= 5B34

h

Positions for determining the zero position of the reference measuring system

Homing

Setting range

(min. value | unit | max. value)

-214748.3647

unit

214748.3647

Subcodes

Lenze setting

Info

C01227/1

0.0000 unit

MCK: Ref. offset reference degree

• Relative traverse path by which the drive traverses

correctly signed with search speed after detection of

the sensor reference signal.

C01227/2

0.0000 unit

MCK: Ref. home position

• Position with which setpoint and actual position are

loaded after completion of homing.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01228 | MCK: Ref. sequence profile

Data type: UNSIGNED_8

Index: 23347

d

= 5B33

h

Number of the sequence profile the absolute position of which will be approached after homing.

Homing

Setting range

(min. value | unit | max. value)

Lenze setting

0

15 0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1