1 "standby" operating mode, Standby" operating mode, Standby – Lenze 8400 HighLine User Manual

Page 507: Operating mode is assumed, 8basic drive functions (mck)

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

507

8

Basic drive functions (MCK)

8.2

Internal interfaces | System block "LS_MotionControlKernel"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.2.3.1

"StandBy" operating mode

The internal "StandBy" operating mode is implicitly assumed if controller inhibit, pulse inhibit, quick

stop and/or DC-injection braking are activated. Thus, there is no setpoint generation by the Motion

Control Kernel in the "StandBy" operating mode.

• If the holding brake control sets a controller inhibit when the holding brake is closed, the

internal "StandBy" operating mode is not assumed.

• The "StandBy" operating mode cannot be activated via the MCK control word.
• When the "StandBy" operating mode is active, bits 0 ... 3 are set in the MCK status word.

Speed acceptance when the "StandBy" operating mode is quit
In addition to cancelling the controller inhibit, pulse inhibit, quick stop and/or DC injection braking,

a change to another operating mode from "StandBy" also requires a termination of the

magnetisation of the motor (not in case of synchronous motors). If there is a change to a setpoint-

controlled operating mode of the Motion Control Kernel the current speed is transferred to the

speed setpoint.

From version V12.00.00 onwards

, a sensitivity threshold can be set for preventing a drifting of the

motor shaft in

C2611/5

. If the absolute value of the current speed is below the sensitivity threshold,

the value "0" is transferred to the speed setpoint instead of the current speed. The following

illustration shows the issue:

[8-4]

Example: Sensitivity threshold for speed transfer from the "StandBy" operating mode

In the Lenze setting "0.5 %", the sensitivity threshold corresponds to approx. 7.5 rpm at a reference

speed of 1500 rpm set in

C00011

.

Note!

Due to a motor magnetisation of a motor normally standing still, the current speed can

also be non-zero rpm when "StandBy" is quit. If the operating mode now changes to

"Positioning", the transfer of this speed to the speed setpoint may cause a permanent

drifting of the motor shaft, depending on the activated option in

C01216

.

Current speed below sensitivity threshold  speed setpoint = 0

Current speed above sensitivity threshold  speed setpoint = current speed

C02611/5

: Sensitivity threshold (in [%] with regard to reference speed)

v

SetSpeed

ActSpeed

t

0

0

C02611/5

Œ

C02611/5

StandBy

Positioning

StandBy

Positioning

ActSpeed

SetSpeed

1

Advertising