1 status bit "homposavailable, Status bit "homposavailable, 8basic drive functions (mck) – Lenze 8400 HighLine User Manual

Page 504

Advertising
background image

8

Basic drive functions (MCK)

8.2

Internal interfaces | System block "LS_MotionControlKernel"

504

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.2.2.1

Status bit "HomPosAvailable"

Bit 13 ("HomPosAvailable") in the MCK status word 1 shows that the reference position has been

detected and is known in the drive.
An available reference information (bit 13 = "1") and thus a valid measuring system is required for

the following functions:

• Positioning in the "

Positioning

" operating mode in the following (

C01300/1...15

) positioning

modes:

• 1: absolute (beeline)
• 4: absolute (Cw)
• 5: absolute (Ccw)
• 8: absolute (shortest path) to TP
• 11: absolute (Cw) to TP
• 12: absolute (Ccw) to TP

• Response to set software limit positions
• Stopping on breakpoints in the "

Manual jog

" operating mode

• Traversing of a sequence profile with absolute measuring reference in the "

Homing

" mode after

homing is completed

Resetting the reference information
The following events reset bit 13 ("HomPosAvailable") in the MCK status word 1:

• Setting bit 10 ("HomResetPos") in the MCK control word 1
• Overtravelling the 32-bit position display area at the limit ±2147483647 increments when the

cycle (

C1201/1

) = "0 units".

• Change of the position encoder selection in

C00490

• Change of the cycle in

C1201/1

• Writing on the machine parameters if bit 1 ("delete reference when machine data is changed")

is set in

C2652

.

• Machine parameters are cycle (

C1201/1

), gearbox factors (

C1202/1...2

,

C1203/1...2

) and feed

constant (

C1204

).

• The mere writing of these parameters (even when the previous value is used) causes the

reference to be deleted!

• Encoder error when a position encoder is used at the multi-encoder interface
• Resolver error when a resolver is used as position encoder
• Mains recovery at a cycle set unlike "0 units" in

C1201/1

and if the position difference at

reference recovery is higher than 1000 cycles.

Advertising