3 limit position monitoring, 1 software limit positions, Limit position monitoring – Lenze 8400 HighLine User Manual

Page 530: Software limit positions, 8basic drive functions (mck), Stop

Advertising
background image

8

Basic drive functions (MCK)

8.4

Basic settings

530

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.4.3

Limit position monitoring

8.4.3.1

Software limit positions

The parameterisable limit positions are used by the software to limit the traversing range.

• The positive software limit position is set in

C01229/1

and the negative software limit position

is set in

C01229/2

.

[8-15] Definition of the software limit position trigger limits

Stop!

The software limit positions are only evaluated and monitoring if the drive knows the

home position and the software limit positions for the respective operating mode have

been activated (see the following table)!

Operating mode

Effective software limit positions (if home position is known)

Speed follower

Yes (adjustable in

C01219

- bit 3)

Homing

Yes

Manual jog

No (adjustable in

C01230

- bit 3)

Positioning

Yes

Position follower

Yes (adjustable in

C01218

- bit 3)

Error range (actual position)

Set position

Actual position

C01229/1

: Positive software limit position

C01229/2

: Negative software limit position

0

Œ

C01229/1



C01229/2

wMotionState1 - Bit 14: Pos. SW-Limit Detected

wMotionState1 - Bit 15: Neg. SW-Limit Detected

SetPos

1

2 ActPos

t

t

t

0

0

Position

(absolute)

+32767 Incr.

-32767 Incr.

+32767 Incr.

-32767 Incr.

Advertising