C00590 | resp. to switching frequency red, C00592 | resp. to can bus connection, C00592/1 – Lenze 8400 HighLine User Manual

Page 920: C00592/3, C00592/4, C00592/5, C00592/2, C00590, Which, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00590

920

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00590

C00592

Parameter | Name:

C00590 | Resp. to switching frequency red.

Data type: UNSIGNED_8

Index: 23985

d

= 5DB1

h

Response to reduction of the inverter switching frequency (

C00018

)

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00592 | Resp. to CAN bus connection

Data type: UNSIGNED_8

Index: 23983

d

= 5DAF

h

Configuration of monitoring of the CAN interface (group 1)

"CAN on board" system bus

Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C00592/1

0: No Reaction

Response to incorrect telegram for CAN communication

C00592/2

0: No Reaction

Response to "BusOff" (bus system switched off)

C00592/3

0: No Reaction

Response to warnings of the CAN controller

C00592/4

0: No Reaction

Response to communication stop of a CAN bus node

C00592/5

0: No Reaction

Response to an event in the case of monitoring via

heartbeat protocol

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1