17.1.73.4 Synchronising slave drive to master drive

If an angular synchronism of the drives is required (e.g. in printing units), the slave drives must be

positioned to the master position since the FB L_DFSET as a master value can only receive and

process one relative signal. The FB L_DFSET receives the master value via a real-time capable

MotionBus as the system bus (CAN).
For synchronisation purposes, the slave drive is informed cyclically or once about its drive position

by a pulse generated by the master drive. This pulse is either the zero pulse of the master feedback

or the edge of a touch probe sensor. Moreover, a pulse must be generated by the slave drive. Only if

the FB L_DFSET receives both signals, it can execute a synchronisation.

Synchronisation mode - mark correction
For synchronisation, the following modes are available in

C01075/1

:

Mode

Info

0 Synchronisation inactive

Lenze setting

1 Permanent synchronisation without enable via the

bZeroPulse input

• Correction is executed over the shortest possible

path.

The synchronisation only takes place after 2 setpoint

pulses have been received at the bSetTPReceived

input.

(required pulse order: set-actual-set)

• See illustration

[17-37]

.

( 1353)

2 Permanent synchronisation only with enable via the

bZeroPulse input

• When bZeroPulse is set to TRUE, a permanent

zero pulse/touch probe synchronisation is

executed.

• Correction is executed over the shortest possible

path.

10 One-time synchronisation only with enable via the

bZeroPulse input

• An angular difference is compensated over the

shortest possible path.

11 One-time synchronisation only with enable via the

bZeroPulse input

• An angle difference is compensated in CW

direction.

12 One-time synchronisation only with enable via the

bZeroPulse input

• An angular difference is compensated in CCW

direction.

13 One-time synchronisation only with enable via the

bZeroPulse input

• An angular difference is compensated over the

shortest possible path.

Synchronisation takes place after the first setpoint

pulse has been received at the bSetTPReceived input

and/or actual value pulse at the bActTPReceived

input.

(Required clock sequence: Set/actual or actual/set)

• See illustration

[17-38]

.