Ck16: time overflow manual control, Error m, Ck07: travel range limit exceeded – Lenze 8400 HighLine User Manual

Page 664: Ck05: error, following error 1, Ck06: error, following error 2, Will, Message, Ck08: home position unknown, Xx.0184.00153, Xx.0184.00154

Advertising
background image

9

Diagnostics & error management

9.9

Error messages of the operating system

664

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Ck16: Time overflow manual operation [xx.0184.00064]

Ck05: Following error 1 [xx.0184.00153]

Ck06: Following error 2 [xx.0184.00154]

Ck07: Travel range limit exceeded [xx.0184.00155]

Ck08: Home position unknown [xx.0184.00156]

Ck09: Positioning mode invalid [xx.0184.08005]

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

PC manual control: The connection monitoring has

tripped.

• The online connection between the PC and the

controller has been interrupted for a longer period of

time than the timeout set in

C00464/1

.

• Check communication link between PC and

controller.

• Check voltage supply/function of the controller.

• Adjust the timeout (

C00464/1

).

Response (Lenze setting printed in bold)

Setting:

C00595/5

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: Following error limit 1 (

C01215/1

) has been

exceeded.

• Optimise control mode.

• Increase following error limit.

• Deactivate following error monitoring.

Response (Lenze setting printed in bold)

Setting:

C00595/6

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: Following error limit 2 (

C01215/2

) has been

exceeded.

• Optimise control mode.

• Increase following error limit.

• Deactivate following error monitoring.

Response (Lenze setting printed in bold)

Setting:

C00595/7

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The maximum travel distance has been exceeded.

• The maximum travel distance is displayed in

C01213/1

.

• Check profile parameters.

• Deactivate travel range limit monitoring.

Response (Lenze setting printed in bold)

Setting:

C00595/8

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: Home position is unknown.

Perform homing.

Response (Lenze setting printed in bold)

Setting:

C00595/9

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The positioning mode defined via the

wPosProfileMode input is not supported.

Define a valid positioning mode.

Advertising