7technology applications – Lenze 8400 HighLine User Manual

Page 465

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

465

7

Technology applications

7.5

TA "Switch-off positioning"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Switch-off positioning
bJogCtrlInputSel1

bJogCtrlInputSel2

BOOL

Selection inputs for a binary coded selection of the switch-off position 1 ... 3

• Activation of the signal pairs bJogCtrlSlowDown1/bJogCtrlStop1,

bJogCtrlSlowDown2/bJogCtrlStop2 or bJogCtrlSlowDown3/bJogCtrlStop3

according to the

Truth table for activating the pre-switch off

.

bJogCtrlRfgIn

BOOL

Ramping down of the setpoint generator in the downstream

L_NSet

FB according to

the

Truth table for activating the pre-switch off

bJogCtrlJog1

bJogCtrlJog2

BOOL

Selection inputs for fixed changeover setpoints (JOG setpoints) for the main setpoint

• If the pre-switch off is inactive (bJogCtrlInputSel1 and bJogCtrlInputSel2 are both

set to FALSE), the two control signals are passed through 1:1 to the downstream

FB

L_NSet

.

• To achieve the desired behaviour (starting at high speed, pre-switch off at low

speed), both inputs must be set to TRUE.

• Fixed setpoint 2 must be less than fixed setpoint 3!

Otherwise, the drive will start at a low speed and accelerate after the pre-switch

off.

• If in additional to the inputs bJogCtrlJog1 and bJogCtrlJog2 the selection inputs

bJogSpeed4 and bJogSpeed8 are assigned, different fixed setpoints can result

from this and the drive may travel with different speeds than selected via

bJogCtrlJog1 and bJogCtrlJog2.

bJogCtrlSlowDown1

bJogCtrlSlowDown2

bJogCtrlSlowDown3

BOOL

Activation of fixed setpoint 2 in the downstream

L_NSet

FB

• These inputs only have a function if they have been previously activated via

bJogCtrlInputSel1 and bJogCtrlInputSel2 (see

Truth table for activating the pre-

switch off

).

bJogCtrlStop1

bJogCtrlStop2

bJogCtrlStop3

BOOL

Ramping down of the ramp function generator in the downstream

L_NSet

FB

• These inputs only have a function if they have been previously activated via

bJogCtrlInputSel1 and bJogCtrlInputSel2 (see

Truth table for activating the pre-

switch off

).

bJogSpeed4

bJogSpeed8

BOOL

Selection inputs for fixed changeover setpoints (JOG setpoints) for the main setpoint

• A fixed setpoint for the setpoint generator can be activated instead of the main

setpoint via these selection inputs.

• The selection inputs are binary coded.

• For a detailed functional description see the

L_NSet

FB.

bJogRamp1 ... bJogRamp8

BOOL

Selection inputs for alternative acceleration/deceleration times for the main

setpoint

• The four selection inputs are binary coded, therefore 15 alternative

acceleration/deceleration times can be selected.

• For main setpoint nMainSetValue_a, the set acceleration time (

C00012

) and

deceleration time (

C00013

) are active in the case of the binary coded selection "0"

(all inputs = FALSE or not assigned).

• Alternative acceleration times are selected in

C00101/1...15

.

• The selection of the alternative deceleration times is carried out in

C00103/1...15

.

• For a detailed functional description see the

L_NSet

FB.

MCK basic functions
bMBrakeRelease

BOOL

Holding brake control

: Release/apply brake

• In conjunction with the operating mode selected in

C02580

(Lenze setting: "Brake control off").

FALSE Apply brake.

• During automatic operation, the internal brake logic controls the

brake.

TRUE Release brake manually (forced release).

Note!

The brake can also be released if the controller is inhibited!

• During automatic operation, the internal brake logic is

deactivated and the brake is released (supervisor operation). If a

controller inhibit has been set by the brake control, it will be

deactivated.

• In semi-automatic operation, the brake is released including

feedforward control.

Identifier

Data type

Information/possible settings

Advertising