1 optional settings, Optional settings, 4device control (dctrl) – Lenze 8400 HighLine User Manual

Page 107

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

107

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.5.1

Optional settings

From version 10.00.00

, the options described in the following for the quick stop function can be

activated in

C00104/1

. In the Lenze setting, no option is activated.

Standstill position-controlled
When bit 0 is set in

C00104/1

, the position control is activated at standstill.

• The basic conditions are shown in the

Flow diagram

for the quick stop function.

• More conditions for a proper function:

The inputs nPosCtrlOutLimit_a and nPosCtrlPAdapt_a at the

LS_MotorInterface

system block

have to be set to 100 % (default setting for all technology applications).

Ramp position-controlled
If bit 1 is set in

C00104/1

, the position control is activated while ramping down.

• The basic conditions are shown in the

Flow diagram

for the quick stop function.

• More conditions for a proper function:

The inputs nPosCtrlOutLimit_a and nPosCtrlPAdapt_a at the

LS_MotorInterface

system block

have to be set to 100 % (default setting for all technology applications).

Continue following error

(from version 15.00.00)

If bit 2 is set in

C00104/1

, the current following error is continued if the quick stop with position

control is activated while ramping down.

Starting value is the setpoint speed

(from version 15.00.00)

If bit 3 is set in

C00104/1

, the starting value for quick stop is the setpoint speed. If the bit is not set,

the starting value for quick stop is the actual speed if this does not derive more than 5 rpm from the

setpoint. This serves to prevent a jump to a setpoint with a high deviation.

Use position encoder

(from version 15.00.00)

If bit 4 is set in

C00104/1

, the position encoder is used instead of the speed encoder for quick stop

with position control.

• The basic conditions are shown in the

Flow diagram

for the quick stop function.

Advertising