Parameter list | C00700

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00700/6

0: Not connected

LA_NCtrl

: nPIDActValue_a

Input for actual PID controller value

C00700/7

16000: LS_AnalogInput: nIn1_a

LA_NCtrl

: nMainSetValue_a

Input for main speed setpoint

C00700/8

0: Not connected

LA_NCtrl

: nAuxSetValue_a

Input for additional speed setpoint

C00700/9

0: Not connected

LA_NCtrl

: nGPAnalogSwitchIn1_a

Input for analog switch - analog signal 1

C00700/10

0: Not connected

LA_NCtrl

: nGPAnalogSwitchIn2_a

Input for analog switch - analog signal 2

C00700/11

0: Not connected

LA_NCtrl

: nGPArithmetikIn1_a

Input for arithmetic function - analog signal 1

C00700/12

0: Not connected

LA_NCtrl

: nGPArithmetikIn2_a

Input for arithmetic function - analog signal 2

C00700/13

0: Not connected

LA_NCtrl

: nGPMulDivIn_a

Input for analog signal for multiplication/division

C00700/14

0: Not connected

LA_NCtrl

: nGPCompareIn1_a

Input for comparison operation - analog signal 1

C00700/15

0: Not connected

LA_NCtrl

: nGPCompareIn2_a

Input for comparison operation - analog signal 2

C00700/16

0: Not connected

LA_NCtrl

: nVoltageAdd_a

Input for additive voltage boost

C00700/17

0: Not connected

LA_NCtrl

: nPIDInfluence_a

Input for influence signal of PID controller correcting

variable

C00700/18

0: Not connected

LA_NCtrl

: nPIDSetValue_a

Input for PID controller setpoint

C00700/19

0: Not connected

LA_NCtrl

: nPWMAngleOffset

Input for pulse width modulation phase offset

C00700/20

0: Not connected

LA_NCtrl

: nBoost_a

Input for additional setpoint for motor voltage at speed

= 0

C00700/21

0: Not connected

LA_NCtrl

: wSMCtrl

Interface to the optional safety system

C00700/22

0: Not connected

Reserved

C00700/23

0: Not connected

Reserved

C00700/24

0: Not connected

Reserved

C00700/25

0: Not connected

Reserved

C00700/26

0: Not connected

LA_NCtrl

: wFreeIn1

Input for user signal 1

C00700/27

0: Not connected

LA_NCtrl

: wFreeIn2

Input for user signal 2

C00700/28

0: Not connected

LA_NCtrl

: wFreeIn3

Input for user signal 3

C00700/29

0: Not connected

LA_NCtrl

: wFreeIn4

Input for user signal 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00700 | LA_NCtrl: Analog connection list

Data type: UNSIGNED_16

Index: 23875