10 ls_disfree_b, 10 ls_disfree_b 5, Ls_disfree_b – Lenze 8400 HighLine User Manual
Page 1525: 17 function library
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1525
17
Function library
17.2
System blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.2.10
LS_DisFree_b
This system block displays 16 arbitrary digital signals of the application on a bit coded display code.
Inputs
Parameter
Identifier
Data type
Information/possible settings
bDis1 ... bDis16
BOOL
From version 11.00.00 onwards:
bC480_B0 ... bC480_B16
Inputs for arbitrary digital signals of the application
Note:
From version 11.00.00
the inputs are named according to the display
parameter for an easier allocation.
Parameter
Possible settings
Info
0x0000
0xFFFF Display of the digital signals as
hexadecimal values which are
applied at the bDis1 ... bDis16 inputs
Bit 0 Signal level at the bDis1 input
Bit 1 Signal level at the bDis2 input
Bit 2 Signal level at the bDis3 input
... ...
Bit 15 Signal level at the bDis16 input
E'LV
E'LV
E'LV
E'LV
E'LV
&
/6B'LV)UHHBE
%LW
%LW
%LW
%LW
%LW