Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

799

15

Parameter reference

15.2

Parameter list | C00003

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00003

C00002/32

0: Off / ready

Check password

From version 06.00.00

Password protection

C00002/33

0: Off / ready

Delete password

From version 06.00.00

Password protection

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_8

Index: 24573

d

= 5FFD

h

Parameter | Name:

C00003 | Status of last device command

Data type: UNSIGNED_8

Index: 24572

d

= 5FFC

h

Status of the device command executed last (

C00002

).

Note:

Before switching off the supply voltage after carrying out a device command, check whether the device command

has been carried out successfully via the status display!

Drive control (DCTRL)

:

Device commands

Selection list

(read only)

Info

0 Successful

Device command has been executed successfully.

1 Command unknown

Device command implausible or unknown to the system.

2 Password protection

Unauthorised access for requested device command.

Password protection

3 Time-out

Device command could not be processed in the defined

time (timeout).

4 System fault
5 Command server assigned
6 Controller inhibit required

10 Memory module binding error

Device personalisation

11 Password too short

Password protection

12 Wrong password
13 Password already set
14 Password not assigned
20 Setting the hiperface position failed

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1