2 homing mode, Homing mode, Ant for – Lenze 8400 HighLine User Manual

Page 549: Homing modes, 8basic drive functions (mck)

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

549

8

Basic drive functions (MCK)

8.6

Homing

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.6.1.2

Homing mode

Specify the referencing mode in

C01221

, i.e. the way in which referencing is to take place.

• For reference setting, the referencing mode "100" is to be selected in

C01221

.

• For a reference search,

C01221

contains referencing modes "4"..."15" which can be selected

from.

Internal interfaces
The switches/sensors are evaluated via the following internal interfaces:

Referencing mode

C01221

Evaluated signals/sensors

Touch probe sensor

(Sensor reference signal)

Travel range limit switch

Pre-stop mark at

bHomingMark

Negative limit switch

Positive limit switch

4

*

5

*

6

7

8

9

10

11

12

13

14

Positive direction of rotation to torque limit.

15

Negative direction of rotation to torque limit.

100

Set reference directly.

* From version 14.00.00

Switch/sensor

Internal interface for digital input signal

Touch probe sensor

(Sensor reference signal)

Up to and including version Version 05.xx.xx

, a signal at digital

input DI3 is automatically interpreted as TP sensor signal with

level sensitivity.

• That way, TP sensitive homing modes can be used even if high

TP precision is not available.

• In this case, the search speed must be selected in order that the

signal at DI3 will be detected.

From version 06.00.00

, high-precision homing with touch probe

is supported.

• The touch probe signal source can be selected in

C01246/1

.

• If the reference signal is to follow a real touch probe, configure

the touch probe signal accordingly.

Touch probe detection

( 353)

Note: In case of setting "0: No TP" in

C01246/1

, the digital input

DI3 is continued to be used as signal source. An inversion of DI3

via

C00114

is considered.

Positive travel range limit switch

bLimitSwitchPos

Negative travel range limit switch

bLimitSwitchNeg

Pre-stop mark/pre-stop signal

bHomingMark

• This input has to be connected to the corresponding digital input

to which the pre-switch off sensor is connected.

• The edge sensitivity of this input and the response to the pre-

switch off signal depend on the selected homing mode (see the

following description of the homing modes).

Advertising