2 acceleration override, Acceleration override, 8basic drive functions (mck) – Lenze 8400 HighLine User Manual

Page 595

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

595

8

Basic drive functions (MCK)

8.11

Override

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.11.2

Acceleration override

Activating override
If control bit 12 (EnableAccOverride) in the

MCK control word

has been set to "1", an acceleration

override takes place in accordance with the stipulated override value.
If the Motion Control Kernel is downstream from the MCKInterface in the circuit, the

L_MckCtrlInterface

FB provides the following process input for activating the acceleration override:

Stipulate override value
The override value is stipulated via the nAccOverride_a input at the

LS_MotionControlKernel

SB. The

override value is a percentage of the maximum acceleration that has been set for the respective

operating mode (referencing, manual jog, positioning etc.) in the corresponding profile parameter.
The acceleration override results in a deceleration override. Both ramps are evaluated by

multiplication by the acceleration override until the deceleration process sets in.

Deactivate override
If control bit 12 (EnableAccOverride) is reset to "0", travelling takes place at the acceleration rates

specified by means of the profile parameters. "Ramping up" from the acceleration defined with

override to the acceleration set in the profile takes place immediately in this case.

Identifier

Data type

Information/possible settings

bEnableAccOverride

BOOL

Acceleration override

TRUE Activate acceleration override

Identifier

Data type

Information/possible settings

nAccOverride_a

INT

Value for acceleration override

• Percentage multiplier (0 ... 199.99 %) for the currently active acceleration.

• 16384 ≡ 100 % of the parameterised acceleration of the corresponding operating

mode.

• If the override value is 0 %, acceleration ceases.