C01000 | mctrl: status, C01001 | manual entry of motor type, C01000 – Lenze 8400 HighLine User Manual

Page 1033: Displays the set mot, C01001/1, 15 parameter reference

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1033

15

Parameter reference

15.2

Parameter list | C01000

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01000

C01001

Parameter | Name:

C01000 | MCTRL: Status

Data type: UNSIGNED_16

Index: 23575

d

= 5C17

h

From version 10.00.00

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 SLPSM: Speed closed-loop control

1 ≡ The sensorless control for synchronous motors is in

the closed-loop controlled operation (|n

Setpoint

| >

n

C00996

).

Sensorless control for synchronous motors (SLPSM)

Bit 1 SLPSM: Speed open-loop control

From version 12.00.00

1 ≡ The sensorless control for synchronous motors is in

the open-loop controlled operation (|n

Setpoint

| > n

C00996

).

Sensorless control for synchronous motors (SLPSM)

Bit 2 Motor ASM

From version 12.00.00

1 ≡ Set motor type is "Asynchronous motor"

Bit 3 Motor PSM

From version 12.00.00

1 ≡ Set motor type is "Synchronous motor"

Bit 4 Encoder open circuit: V/f linear active

From version 15.00.00

1 ≡ Due to an encoder open circuit, it has been internally

switched to the encoderless V/f characteristic control to

avoid impermissible motor movements.

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01001 | Manual entry of motor type

Data type: UNSIGNED_8

Index: 23574

d

= 5C16

h

From version 14.00.00

Selection list

0 Automatic
1 ASM
2 PSM

Subcodes

Lenze setting

Info

C01001/1

0: Automatic

Manual entry of motor type

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1