15.2

Parameter list | C00176

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00176

C00177

C00178

C00179

Parameter | Name:

C00176 | Undervoltage threshold for mains OFF

Data type: UNSIGNED_16

Index: 24399

d

= 5F4F

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00177 | Switching cycles

Data type: UNSIGNED_32

Index: 24398

d

= 5F4E

h

Counter of different switching cycles and stressful situations
Display range

(min. value | unit | max. value)

0

2147483647

Subcodes

Info

C00177/1

Number of mains switching cycles

C00177/2

Number of switching cycles of the output relay

C00177/3

Short circuit counter

C00177/4

Earth fault counter

C00177/5

"Clamp" counter

C00177/6

Counter for "safe torque off" (STO) after power-on

From version 12.00.00

C00177/7

Counter for controller inhibit via terminal after power-on

From version 12.00.00

C00177/8

Counter for pulse inhibit (IMP) after power-on

From version 12.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00178 | Elapsed-hour meter

Data type: UNSIGNED_32

Index: 24397

d

= 5F4D

h

Display of operating hours in seconds
Display range

(min. value | unit | max. value)

0

s

2147483647

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00179 | Power-on time meter

Data type: UNSIGNED_32

Index: 24396

d

= 5F4C

h

Display of the power-on time in seconds
Display range

(min. value | unit | max. value)

0

s

2147483647

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1