Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

603

8

Basic drive functions (MCK)

8.12

Holding brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.12.2.2

Functional settings

The following bit coded functional settings for the holding brake control can be made in

C02582

:

Bit

Option

Info

Bit 0 bMBrakeReleaseOut invert.

Activation of inverted control

• "1" ≡ Inverted logic of the trigger signal for the holding brake

control switching element

Bit 1 Horizontal brake protection

Brake response in case of pulse inhibit

• "1" ≡ In the case of a pulse inhibit, the actual speed value is

monitored which must reach the "Close" threshold value to cause

the holding brake to be applied.

Note:

• This function is only active if bit 3 (horizontal/winding

technology) is set as well. The function is used in order that, when

the controller is inhibited, the holding brake of a drive with

horizontal traverse path does not wear out during rotation.

• With vertical motion (bit 3 = 0), this function is not active.

Especially with hoists and activated pulse inhibit of the controller,

an immediate application of the brake is essential for safety-

related reasons!

Bit 2 with hoist inv. feedfwd. control

Direction of feedforward control with vertical/hoist technology:

• "0" ≡ Positive direction

• "1" ≡ Negative direction

Note:

Reversal (Ccw) is then considered.

Bit 3 Horizontal application

Direction of movement of the axis

• "0" ≡ The axis performs vertical movements. Gravitational

acceleration causes movements.

• "1" ≡ The direction of the axis is horizontal or rotary. The

gravitational acceleration does not cause any movement.

Bit 4 Feedforward control C2581

(from version 06.00.00)

Selection of the feedforward control value

• "0" ≡ Automatic selection.

• The torque saved at the last stop is used.

• "1" ≡ Manual selection.

bMBrakeStartValue2 = FALSE: The feedforward control value 1

set in

C02581/4

is used.

bMBrakeStartValue2 = TRUE: The feedforward control value set

in

C02581/5

is used.

Bit 5 Feedback monitoring

(from version 06.00.00)

Activation of status monitoring

• "1" ≡ The bMBrakeApplied input for status detection of the brake

(via a switching contact at the brake) is monitored after the

waiting time set in

C02589/3

has expired.

Bit 6 Sync ramp L_NSet_1

(from version 11.00.00)

Selection of the ramp time for the synchronisation process to

setpoint speed after the brake opening time has elapsed

Revised behaviour from version 11.00.00:

• "1" ≡ The ramp time of the effective acceleration of the ramp

function generator (

L_NSet_1

) is used (Lenze setting).

• "0" ≡ As before, the ramp time set in

C02610/1

is used.

Note:

The changeover can be dynamically both via the ramp parameter

and via bit 6.

Bit 7 Reserved

Advertising