01.99

12 Functional Descriptions

12.20.8 Configuration help for generator operation and emergency retraction

12.20.8.2

Activating autonomous drive emergency retraction in
case of PLC failure or 5 V undervoltage (as from SW 6.3)

No NCK failure, activation only when in operative mode, no run up in the general reset mode

Activating

Clearing for activation of the autonomous drive emergency retraction is implemented according
to the function via the following MD bits:

5022

Delay of the

NC ready

signal for

1 IPO cycle

in case of

PLC failure

or 5 V
under-

voltage

5 V under-

voltage

Retraction in
case of PLC

failure

NC MD

Bit No.

7

6

5

4

3

2

1

0

5022.4=1

Clearing for activation of the autonomous drive emergency retraction in case
of PLC failure

5022.5=1

Clearing for activation of the autonomous drive emergency retraction in case
of 5 V undervoltage

5022.7=1

Delay of the NC ready signal for 1 IPO cycle in case of PLC failure of 5 V
undervoltage

5022.7=0

No delay of the NC ready signal for 1 IPO cycle in case of PLC failure or 5 V
undervoltage

Default setting of bit is 0.

Reactions

Display of the applicable alarm on (POWER ON), stopping the NCK CPU and execution of the
autonomous drive emergency retraction.

After POWER ON, the NCK instantly runs in normal operational mode instead of the then
startup mode.

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

12–231

SINUMERIK 840C (IA)

Advertising