12.93

7 Drive Machine Data (SIMODRIVE Drive MD)

7.1.2 MSD MD (data description - SW 3)

Status of binary inputs

11

Default value

Lower output limit

Upper output limit

Units

Hex

Active

at once

Display machine data for the status of the binary inputs.

Value table:

Bit 0

Not assigned

Bit 1

Bit 2

Bit 3

Image terminal 663 (module-specific
pulse suppression IMPFR)

Image terminal 63 of I/RF unit
(central drive pulse suppression
REIMSP)

Sum signal pulse enable:
- Stored hardware sum signal

HWFRGOUT

- Pulse enable by PLC via 611D

control word

0: Pulse enable
1: Pulse disable

Bit 4

"Heat sink of power section XKKT too
hot" message

0: Overtemperature
1: Normal temperature

Bit 5

Image terminal 112 of I/RF unit (set-up
mode XEINR message)

0: Set-up mode
1: Normal mode

Bit 6

Image terminal 64 of I/RF unit (central
drive enable setpoint = 0)

0: Controller enable
1: Regenerative braking

Bit 7

Not assigned

Bit 8

Image terminal 5 of I/RF unit
(motor/power section temperature
prewarning X12T)

0: Normal range
1: Limit value exceeded

Bit 9-15

Not assigned

Speed for max. motor operational speed motor 1

14

Default value

Lower input limit

Upper input limit

Units

Maximum motor

speed

Max. speed

Max. speed

rev/min

Active

at once

Machine data MD 14 defines the maximum operating speed of the main spindle motor. It acts
as the reference value of the speed setpoint interface.

Note:

The velocity of a main spindle is matched in NC-MD 4030 (maximum spindle speed). The
motor operating speed which corresponds to this maximum value must be entered in drive-MD
14. Allowance is made for any existing gear ratios in the relationship between NC-MD 4030
and drive-MD 14.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50