09.01

12 Functional Descriptions

12.11.2 ENDAT absolute encoder (SW 5.2 and higher)

Lin. incremental measuring step =

=

*

= 0.002384

µ

m

Linear grid spacing

Pulse multiplication

10 mm

2048

1

4 * 512

The position controller resolution is coarser than the linear incremental measuring step and
therefore determines the positioning accuracy. If the incremental measuring step were coarser
than the position controller resolution, the incremental measuring step would determine the
position controller resolution.

Rotary EnDat measuring step =

= 1.22 * 10

-4

rev.

1 revolution

2048 * 4

EnDat measuring step =

= 1.22

µ

m

2048 * 4

10 mm

NC-MD 1264* =

=

*

= 4

Linear grid spacing

Lin. EnDat measuring step

2048 *

10 mm

2048 * 4

10 mm

Example

LC 181:

Grid spacing, finest track

16

µ

m

EnDat measuring step

0.1

µ

m

Internal pulse multiplication

4

External pulse multiplication (interpolation)

512

Position controller resolution

0.5

µ

m = 0.5 * 10

-3

mm

Lin. incremental measuring step =

=

= 0.0078125

µ

m

Lin. grid spacing

Pulse multiplication

16

µ

m

4 * 512

NC MD 1264* =

=

= 160

Lin. grid spacing

Lin. EnDat measuring step

0.1

µ

m

16

µ

m

Calculation of the grid spacing with EnDat absolute encoders using 611D:

Meas. system 1: 1264*=

Drive MD 1022

Drive MD 1005

Meas. system 2: 1264*=

Drive MD 1032

Drive MD 1007