Siemens SINUMERIK 840C User Manual

Page 978

Advertising
background image

09.01

12 Functional Descriptions

12.19.5 Interpolation and compensation with tables

Data type

Significance

Data No.

within data

type

Data type

for

@30c/40c

or T para.

G fct. for

IKA

G fct. for

CGI

Only valid

with IKA

Stage 2

Weighting input A
(denominator)

1 to 32

19

-

Function not

available

x

Input B (number)

1 to 32

25

G411

Function not

available

x

Input B (type)

1 to 32

26

G411

Function not

available

x

Output (number)

1 to 32

3

G411

G401

Output (type)

1 to 32

33

G411

G401

Weighting factor
output (numerator)

1 to 32

4

G412

G402/G403

Weighting factor
output (denominator)

1 to 32

30

G412

G402/G403

x

Max. output value
upper limit (not for
compensation)

1 to 32

31

-

-

x

Unit

EGF

Min. output value
lower limit (not for
compensation)

1 to 32

32

-

-

x

EGF

Max. change of
output value (not for
compensation)

1 to 32

34

-

-

x

Unit

Value x EGF

IPO

Internal status of
IKA (see following
table)

37

-

-

x

Value actual input A

1 to 32

21

-

-

x

Table input value

1 to 32

22

-

-

x

Value actual input B

1 to 32

27

-

-

x

Actual output value

1 to 32

35

-

-

x

Interpolat. point no.

1 to 32

36

-

-

x

Actual switching
state

1 to 32

37

-

-

x

%IKA1 IKA

configuration

Type definition of data type 37 "Internal condition of IKA":

Final conditions of IKA:

0:

IKA deactivated

1:

IKA deactivated

2:

IKA deactivated in plus direction

3:

IKA deactivated in minus direction

Intermediate conditions of IKA during transition to a new final condition:

4:

IKA is deactivated

5:

IKA is activated and deactivated

6:

IKA is switched over

7:

IKA is deactivated position-dependently

8:

IKA is deactivated position-dependently in plus direction

9:

IKA is deactivated position-dependently in minus direction

10:

IKA is switched on and over position-dependently

11:

IKA is switched on and over position-dependently in the plus direction

12:

IKA is switched on and over position-dependently in the minus direction

13:

IKA is switched over position-dependently

14:

IKA is switched over position-dependently in the plus direction

15:

IKA is switched over position-dependently in the minus direction

16:

IKA is stopped

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50