Siemens SINUMERIK 840C User Manual

Page 1033

Advertising
background image

12 Functional Descriptions

04.96

12.25 Flexible memory configuration (SW 4 and higher)

12.25

Flexible memory configuration (SW 4 and higher)

12.25.1

Corresponding data

Machine data

•

NC MD 60000 Size of UMS memory

•

NC MD 60001 Size of part program memory

•

NC MD 60002 Number of IKA points

•

NC MD 60003 Memory for drive software for MSD

•

NC MD 60004 Memory for drive software for FDD

•

NC MD 60005 Number of tools

•

NC MD 60006 Number of TO parameters per tool

•

NC MD 60007 Number of channel-specific R parameters

•

NC MD 60008 Number of central R parameters

•

NC MD 60009 Unassigned residual memory, D-RAM

•

NC MD 60010 Unassigned residual memory, S-RAM

•

NC MD 60011 NC module memory configuration

•

NC MD 6100*

Number of block buffers in block memory in channels 1 to 6

•

NC MD 6200*

Number of axis-specific measured values for the "Extended measurement"
function

•

NC MD 60013 Memory for real axes (as from SW 5)

•

NC MD 61020 Memory for ”Extended overstore” (as from SW 5)
to 61025

General

The "Flexible memory configuration" function allows the user to influence the memory page
allocation for:

•

User data

–

Part program data

–

UMS data

–

IKA data

–

R parameters

–

TO data

–

Data for real axes

–

Data for extended overstore

•

Drive software

In the case of analog drive systems, the memory space reserved for digital drive software
can be used to store user data.

•

Number of axis-specific measured values:

For the "Extended measurement" function.

•

Number of block buffers in block memory:

Depending on the capacity utilization of individual channels, it is possible to define on a
channel-specific basis the maximum permissible number of part program blocks which may
be pre-decoded during processing.

12–258

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising