Siemens SINUMERIK 840C User Manual

Page 503

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

07.97

7.3.2 Drive MD (data description)

Format of power section code number:

Value table:

Code

Drive type

Current

PS

Comments

6

MSD

24/32/32 A

50 A

7

MSD

30/40/51 A

80 A

8

MSD

45/60/76 A

120 A

9

MSD

60/80/102 A

160 A

A

MSD

85/110/127 A

200 A

B

MSD

120/150/193 A

300 A

C

MSD

200/250/257 A

400 A

D

MSD

45/60/76 A

108 A

11

FDD

3/6 A

8 A

12

FDD

5/10 A

15 A

14

FDD

9/18 A

25 A

16

FDD

18/36 A

50 A

17

FDD

28/56 A

80 A

19

FDD

56/112 A

160 A

1A

FDD

70/140 A

200 A

28

FDD

140/210 A

400 A

as from SW 4.1

Transistor limit current, power section

1107

Default value

Lower input limit

Upper input limit

Units

200.0

1.0

500.0

A

Active on

Power On

Input of maximum permissible current of power section. This machine data is automatically
parameterized for Siemens power sections by the machine data "Power section code"
(MD 1106).

Caution:

This data serves as the basis for normalizing the current actual value sensor and must not be
changed
by the user after automatic presetting of its values.

7–88

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising